Avlink CX-2088 Manuel d'utilisateur Page 17

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 31
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 16
CX Matrix Switching SystemUser Manual
16
B. If your PC provides RS-485please follow conection as shown in Figure 5-10 below:
Figure 5-10
NOTE: 1. RS-485 baud rate: 9600bps, no odd or even calibration address8bit data transmission
address1bit stop address96N81
2. Connect your PC RS-485 port to the Matrix RS-485 port as follows:
TX+ TX+
TX- TX-
RX+ RX+
RX- RX-
3. Serial connection between Matrix RS-485 ports as shown below:
TX+ TX+
TX- TX-
RX+ RX+
RX- RX-
4. Each DIP sw1-5 address must not set to same ID number.