YX Matrix Switching SystemUser Manual
15
5.0.3.4 YX Matrix System and Control System Connection
A. If PC provides RS-232connection is as in Figure 5-9 below:
Figure 5-9
NOTE: 1. For RS-232 connection refer to previous Figure for operation
2. RS-232 or RS-485 baud rates: 9600bps, no odd or even calibration address, 8bit data
transmission address, 1bit stop address96N81
3. Serial connection between Matrix RS-485 as follows:
TX+ TX+
TX- TX-
RX+ RX+
RX- RX-
4. Each DIP sw1-5 address must not set to same ID address.